Daikin McQuay Maverick™ I commercial packaged rooftop systems (3 to 25 tons) are ideal for one to three-story buildings, including offices, schools, libraries and strip malls.  They combine the lower installation costs and interior space savings of a roof-mounted system with the operating and maintenance efficiencies of central heating and cooling systems.

Maverick I rooftop units are designed from the ground up with the latest features and benefits required to compete in today’s market:

  • Ideal for new, retrofit, or replacement applications on low rise buildings
  • Lower installation costs and interior space savings
  • Standard low-leak dampers for superior resistance to air leakage and reduced energy costs
  • Scroll compressors for efficient cooling operation and dependability
  • Two-circuit refrigerant design for high reliability
  • Easy access to mechanical components which promotes routine maintenance and can reduce service costs
  • Non-corrosive, double-sloped drain pans per ASHRAE Standard 62.1-2004 for good indoor air quality
  • Totally enclosed condenser fan motors for reliable operation
  • Optional DDC controls
  • Optional LonWorks® or BACnet® communication options for integration into a building automation system
  • Non-ozone depleting R-410A refrigerant

 

Physical Data - MPS 003 through 006

ModelMPS
3 ton4 ton5 ton6 ton
Cooling performance
Gross cooling BTU [kW]36,800
[10.78]
50,000 [14.65]61,000 [17.87]76,000 [22.27]
EER/IEER213 / 11.413 / 11.413 / 11.1N/A / 11.5
Nominal airflow/AHRI airflow (cfm) [L/s]1200 [566]1600 [755]2000 [944]2400/2400 [1133/1133]
Net cooling BTU [kw]35,400 [10.37]48,000 [14.06]59,000 [17.29]73,000 [21.39]
Net sensible BTU [kW]26,200 [7.68]35,600 [10.43]42,000 [12.31]53,900 [15.79]
Net latent BTU [kW]9200 [2.7]12,400 [3.63]17,000 [4.98]19,100 [5.6]
Net system power kW3.14.195.326.31
Compressor(s)
Type/numberScroll/1Scroll/1Scroll/1Scroll/1
Gas heating performance
Steady stage efficiency %81818181
Number of stages1112
Gas connection size1/2"1/2"1/2"1/2"
Heating input (BtuH)80,000/120,00080,000/135,000100,000/135,00075,000/150,000
Heating output (BtuH)64,800/97,20064,800/109,40081,000/109,40060,750/121,500
Temperature rise °F30 - 8030 - 8025 - 7030 - 60
Sound
Outdoor rating (dB)78788388
Outdoor coil
Fin typeLouveredLouveredLouveredLouvered
Tube typeRifledRifledRifledRifled
Tube size OD (in.) [mm]3/8 [9.5]3/8 [9.5]3/8 [9.5]3/8 [9.5]
Face area (sq. ft) [sq. m]16.91 [1.57]16.56 [1.54]16.56 [1.54]13.5 [1.25]
Rows (FPI) [fpcm]1/22 [9]2/22 [9]2/22 [9]1 / 22 [9]
Indoor coil
Fin typeCorrugatedCorrugatedCorrugatedLouvered
Tube typeRifledRifledRifledRifled
Tube size OD (in.) [mm]3/8 [9.5]3/8 [9.5]3/8 [9.5]0.375 [9.5]
Face area (sq. ft) [sq. m]5.17 [0.48]5.17 [0.48]5.17 [0.48]13.5 [1.25]
Rows (FPI) [fpcm]2/17 [7]3/15 [6]3/16 [6]2 / 18 [7]
Refrigerant controlTx valvesTx valvesTx valvesCapillary tube
Drain connection (in.) [mm]3/4 [19.00]3/4 [19.0]1 [19.05]1 [25.4]
Condenser fan
TypePropellerPropellerPropellerPropeller
No. used/diameter (in.) [mm]1/24 [609.6]1/24 [609.6]1/24 [609.6]2/24 [609.6]
Drive type/No. of speedsDirect/1Direct/1Direct/1Direct/1
CFM [L/s]3680 [1737]3680 [1737]3680 [1737]8000 [3775]
Motor hp1/31/31/32 at 1/3 HP
Motor rpm1075107510751075
Indoor fan
TypeFC CentrifugalFC CentrifugalFC CentrifugalFC Centrifugal
No. used/diameter (in.) [mm]1/10x10 [254x254]1/10x10 [254x254]1/10x10 [254x254]1/11x12 [279x305]
No. motors1111
Motor hp1/21/2 - 3/43/4 - 11 1/2
Motor rpm1075107517251725
Motor frame size48485656
Filter
Fin typeDisposableDisposableDisposableDisposable
FurnishedYesYesYesYes
(No.) size (in.) [mm](2) 1x16x24 [25x406x635](2) 1x16x24 [25x406x635](2) 1x16x24 [25x406x635](6) 2x18x18 [51x457x457]
Refrigerant
Charge oz. [g]96 [2722]165 [4678]160 [4536]190.9 [5412]
Weight
Net weight lbs. [kg]543 [246]580 [263]597 [271]965 [438]
Shipping weight lbs. [kg]550 [249]587 [266]604 [274]1002 [455]
  1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is based on AHRI Standard 210/240 or 360.
  2. EER and/or IEER are rated at AHRI conditions and in accordance with DOE test procedures.
  3. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using ANSI standards.
  4. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270.

Physical Data - MPS 007 through 010

ModelMPS
7 1/2 ton8 ton10 ton
Cooling performance
Gross cooling BTU [kW]88,000 [25.78]101,000 [29.59]123,000 [36.04]
EER/IEER211.2 / 11.811.2 / 12.011.2 / 12.0
Nominal airflow/AHRI airflow (cfm) [L/s]2800/2975 [1321/1404]3200/3200 [1510/1510]4000/3750 [1888/1770]
Net cooling BTU [kw]85,000 [24.9]97,000 [28.42]118,000 [34.57]
Net sensible BTU [kW]66,100 [19.37]74,000 [21.68]88,800 [26.02]
Net latent BTU [kW]18,900 [5.54]23,000 [6.74]29,200 [8.56]
Net system power kW7.538.5910.49
Compressor(s)
Type/numberScroll/1Scroll/2Scroll/2
Gas heating performance
Steady stage efficiency %818181
Number of stages222
Gas connection size1/2" / 3/4"1/2" / 3/4"1/2" / 3/4"
Heating input (BtuH)112,500 / 225,000112,500 / 225,000112,500 / 225,000
Heating output (BtuH)91,125 / 182,25091,125 / 182,25091,125 / 182,250
Temperature rise °F25 - 7040 - 7015 - 55
Sound
Outdoor rating (dB)888888
Outdoor coil
Fin typeLouveredLouveredLouvered
Tube typeRifledRifledRifled
Tube size OD (in.) [mm]0.375 [9.5]0.375 [9.5]0.375 [9.5]
Face area (sq. ft) [sq. m]27 [2.51]27 [2.51]27 [2.51]
Rows (FPI) [fpcm]1/22 [9]2/18 [7]2/22 [9]
Indoor coil
Fin typeLouveredLouveredLouvered
Tube typeRifledRifledRifled
Tube size OD (in.) [mm]0.375 [9.5]0.375 [9.5]0.375 [9.5]
Face area (sq. ft) [sq. m]13.5 [1.25]13.5 [1.25]13.5 [1.25]
Rows (FPI) [fpcm]2/18 [7]2/18 [7]3/18 [7]
Refrigerant control Tx valvesTx valves
Drain connection (in.) [mm]1/1 [25.4]1/1 [25.4]1/1 [25.4]
Condenser fan
TypePropellerPropellerPropeller
No. used/diameter (in.) [mm]2/24 [609.6]2/24 [609.6]2/24 [609.6]
Drive type/No. of speedsDirect/1Direct/1Direct/1
CFM [L/s]8000 [3775]8000 [3775]8000 [3775]
Motor hp2 at 1/3 HP2 at 1/3 HP2 at 1/3 HP
Motor rpm107510751075
Indoor fan
TypeFC CentrifugalFC CentrifugalFC Centrifugal
No. used/diameter (in.) [mm]1/15x15 [381x381]1/15x15 [381x381]1/15x15 [381x381]
No. motors111
Motor hp2 - 32 - 32 - 3
Motor rpm172517251725
Motor frame size565656
Filter
Fin typeDisposableDisposableDisposable
FurnishedYesYesYes
(No.) size (in.) [mm](6) 2x18x18 [51x457x457](6) 2x18x18 [51x457x457](6) 2x18x18 [51x457x457]
Refrigerant
Charge oz. [g]190.9 [5412]154.4/166.6 [4377/4723]172.8/180.8 [4899/5126]
Weight
Net weight lbs. [kg]965 [438]1095 [497]1156 [524]
Shipping weight lbs. [kg]1002 [455]1132 [513]1193 [541]
  1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is based on AHRI Standard 210/240 or 360.
  2. EER and/or IEER are rated at AHRI conditions and in accordance with DOE test procedures.
  3. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using ANSI standards.
  4. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270.

Physical Data - MPS 012 through 025

ModelMPS
12 ton15 ton20 ton25 ton
Cooling performance
Gross cooling BTU [kW]156,000 [45.71]188,000 [55.08]244,000 [71.49]312,000 [91.42]
EER/IEER211 / 11.411.1 / 12.411.1 / 11.410 / 10.1
Nominal airflow/AHRI airflow (cfm) [L/s]5000/4400 [2360/2076]6000/5900 [2831/2784]8000/7725 [3775/3645]10000/9475 [4719/4471]
cooling BTU [kw]148,000 [43.36]182,000 [53.33]234,000 [68.56]294,000 [86.14]
Net sensible BTU [kW]107,600 [31.53]135,700 [39.76]171,600 [50.28]214,100 [62.73]
Net latent BTU [kW]40,400 [11.84]46,300 [13.57]62,400 [18.28]79,900 [23.41]
Net system power kW13.3916.3521.0429.39
Compressor(s)
Type/numberScroll/2Scroll/2Scroll/2Scroll/2
Gas heating performance3
Steady stage efficiency %81818181
No. stages2222
Gas connection size1/2" / 3/4"3/4"3/4"3/4"
Heating input (BtuH)150,000 / 252,000250,000 / 350,000300,000 / 400,000300,000 / 400,000
Heating output (BtuH)121,500 / 204,000203,000 / 284,000243,000 / 324,000243,000 / 324,000
Temperature rise °F15 - 5515 - 6015 - 5510 - 45
Sound
Outdoor rating (dB)88919192
Outdoor coil
Fin typeLouveredLouveredLouveredLouvered
Tube typeMicrochannelRifledRifledRifled
Tube size OD (in.) [mm]1 [25.4]0.375 [9.5]0.375 [9.5]0.375 [9.5]
Face area (sq. ft) [sq. m]27 [2.51]53.3 [4.95]53.3 [4.95]53.3 [4.95]
Rows (FPI) [fpcm]2 / 20 [8]1/22 [9]2/22 [9]2/22 [9]
Indoor coil
Fin typeLouveredLouveredLouveredLouvered
Tube typeRifledRifledRifledRifled
Tube size OD (in.) [mm]0.375 [9.5]0.375 [9.5]0.375 [9.5]0.375 [9.5]
Face area (sq. ft) [sq. m]13.5 [1.25]26.67 [2.48]26.67 [2.48]26.67 [2.48]
Rows (FPI) [fpcm]4 / 15 [6]2/18 [7]3/13 [5]4/15 [6]
Refrigerant controlTx valvesTx valvesTx valvesTx valves
Drain connection (in.) [mm]1 [25.4]1 [25.4]1 [25.4]1 [25.4]
Condenser fan
TypePropellerPropellerPropellerPropeller
No. used/diameter (in.) [mm]2/24 [609.6]4/24 [609.6]6/24 [609.6]6/24 [609.6]
Drive type/No. of speedsDirect/1Direct/1Direct/1Direct/1
CFM [L/s]8000 [3775]16,000 [7550]19,800 [9344]19,800 [9344]
Motor hp2 at 1/2 HP4 at 1/3 HP6 at 1/3 HP6 at 1/3 HP
Motor rpm1075107510751075
Motor frame size56/18456/184184/213213/215
Indoor fan
TypeFC CentrifugalFC CentrifugalFC CentrifugalFC Centrifugal
No. used/diameter (in.) [mm]1/15x15 [381x381]2/18x9 [457x229]2/18x9 [457x229]2/18x9 [457x229]
No. motors1111
Motor hp3, 53, 55, 7-1/27-1/2, 10
Motor rpm1725172517251725
Filter
Fin typeDisposableDisposableDisposableDisposable
FurnishedYesYesYesYes
(No.) size (in.) [mm](6) 2x18x18 [51x457x457](8) 2x25x20 [51x635x508](8) 2x25x20 [51x635x508](8) 2x25x20 [51x635x508]
Refrigerant
Charge oz. [g]159.2/156 [4513/4423]205/211 [5812/5982]402/331 [11397/9384]339/357 [9611/10121]
Weight
Net weight lbs. [kg]1230 [558]2000 [907]2341 [1062]2433 [1104]
Shipping weight lbs. [kg]1267 [575]2100 [953]2441 [1107]2533 [1149]
  1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is based on AHRI Standard 210/240 or 360.
  2. EER and/or IEER are rated at AHRI conditions and in accordance with DOE test procedures.
  3. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using ANSI standards.
  4. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270.

 

  

 

Application Software
Brochures
Catalogs
Control Integration
Installation and Operation Manuals
Physical Data
Replacement Parts Lists
   Click here to view the Replacement Parts Model Index
Revit (BIM) Files